Item details
Width
22.5
Model
Basic device
Height
100
Depth
120
Release-delay
0
With approval according to UL
Yes
With detachable clamps
Yes
With start input
Yes
With feedback circuit
Yes
Number of outputs, safety related, undelayed, with contact
2
Number of outputs, safety related, delayed, with contact
0
Number of outputs, safety related, undelayed, semiconductors
0
Number of outputs, safety related, delayed, semiconductors
0
Number of outputs, signalling function, undelayed, with cont
0
Number of outputs, signalling function, delayed, with contac
0
Number of outputs, signalling function, undelayed, semicondu
0
Number of outputs, signalling function, delayed, semiconduct
0
Type of electric connection
Spring clamp connection
Rail mounting possible
Yes
With muting function
No
Type of safety acc. IEC 61496-1
4
With approval for BG BIA
No
Suitable for monitoring of magnetic switches
Yes
Suitable for monitoring of proximity switches
Yes
Suitable for monitoring of emergency-stop circuits
Yes
Suitable for monitoring of optoelectronic protection equipme
Yes
Suitable for monitoring of position switches
Yes
Suitable for monitoring of tactile sensors
No
Suitable for monitoring of valves
No
Performance level acc. to EN ISO 13849-1
Level e
Stop category acc. to IEC 60204
0
Evaluation inputs
2-channel
SIL according to IEC 61508
3